Shopping Cart

Subtotal $462.4‬0

Download Our VDO Gauges Catalogue

1 2 3 4 5

VDO SingleViu Coolant Temperature Gauge 120°C

Temperature Gauge

Coolant Temperature Gauge (120°C)

Black - Hole: 52 mm - 2 1/16"
Operating voltage: 8-32 Volt DC
Range: 0 - 10 Bar - ISO 1402
Analogue signal: 10 - 184 Ohm
CANBus input: 65274 - 117 - 0x25
Connection cable included

VDO SingleViu Coolant Temperature Gauge 120°C

Temperature Gauge

Coolant Temperature (120°C)

Black - Hole: 52 mm - 2 1/16"
Operating voltage: 8-32 Volt DC
Range: +40°C to +120°C - ISO 1380
Analogue signal: 287.4 - 22.7 Ohm
CANBus input: 65262 - 110 - 0x18
Connection cable included

VDO SingleViu Engine Oil Temperature Gauge 150°C

Temperature Gauge

Engine Oil Temperature Gauge (150°C)

Black - Hole: 52 mm - 2 1/16"
Operating voltage: 8-32 Volt DC
Range: +50°C to +150°C - ISO 1375
Analogue signal: 322.8 - 18.6 Ohm
CANBus input: 65262 - 175 - 0x19
Connection cable included

VDO SingleViu Engine Oil Temperature Gauge 150°C

Temperature Gauge

Engine Oil Temperature Gauge 150°C

Black - Hole: 52 mm - 2 1/16"
Operating voltage: 8-32 Volt DC
Range: +50°C to +150°C - ISO 2426
Analogue signal: 322.8 - 18.6 Ohm
CANBus input: 65262 - 175 - 0x19
Connection cable included

VDO SingleViu Cylinder Temperature Gauge 200°Cr

Temperature Gauge

VDO SingleViu Cylinder Temperature 200°C

Black - Hole: 52 mm - 2 1/16"
Operating voltage: 8-32 Volt DC
Range: +60°C to +200°C - Cylinder
Analogue signal: 482.5 - 14.3 Ohm
CANBus input: Not available
Connection cable included

VDO SingleViu Pyrometer 1000°C

Temperature Gauges

VDO SingleViu Pyrometer 1000°C

Black - Hole: 52 mm - 2 1/16"
Operating voltage: 8-32 Volt DC
Range: 0°C to +1.000°C - ISO 1383
Analogue signal: 4.1 - 37.7 mV
CANBus input: 65270 - 173 - 0x30
Connection cable included

VDO SingleViu Hydraulic Temperature Gauge 250°F

Temperature Gauges

VDO SingleViu Hydraulic Temperature Gauge 250°F

Black - Hole: 52 mm - 2 1/16"
Operating voltage: 8-32 Volt DC
Range: 0°F to +250°F - ISO 1414
Analogue signal: 287.4 - 22.7 Ohm
CANBus input: 65128 - 1638 - 0x21
Connection cable included

VDO SingleViu Coolant Temperature Gauge 250°F

Temperature Gauges

VDO SingleViu Coolant Temperature Gauge 250°F

Black - Hole: 52 mm - 2 1/16"
Operating voltage: 8-32 Volt DC
Range: +100°F to +250°F - ISO 0246
Analogue signal: 450 - 30 Ohm
CANBus input: 65262 - 110 - 0x18
Connection cable included

VDO SingleViu Engine Oil Temperature Gauge 300°F

Temperature Gauge

VDO SingleViu Engine Oil Temperature Gauge 300°F

Black - Hole: 52 mm - 2 1/16"
Operating voltage: 8-32 Volt DC
Range: +100°F to +300°F - ISO 2426
Analogue signal: 322.8 - 18.6 Ohm
CANBus input: 65262 - 175 - 0x19
Connection cable included

VDO SingleViu Cylinder Temperature Gauge 400°F

Temperature Gauges

VDO SingleViu Cylinder Temperature Gauge 400°F

Black - Hole: 52 mm - 2 1/16"
Operating voltage: 8-32 Volt DC
Range: +150°F to +400°F - Cylinder
Analogue signal: 482.5 - 14.3 Ohm
CANBus input: Not available
Connection cable included

VDO SingleViu Pyrometer 2000°F

Temperature Gauges

VDO SingleViu Pyrometer 2000°F

Black - Hole: 52 mm - 2 1/16"
Operating voltage: 8-32 Volt DC
Range: 0°F to +2.000°F - ISO 1383
Analogue signal: 4.1 - 37.7 mV
CANBus input: 65270 - 173 - 0x30
Connection cable included

VDO SingleViu Coolant Temperature Gauge 120°C

Temperature Gauges

VDO SingleViu 0246 Coolant Temperature Gauge 120°C

Black - Hole: 52 mm - 2 1/16"
Operating voltage: 8-32 Volt DC
Range: +40°C to +120°C - ISO 0246
Analogue signal: 287.4 - 22.7 Ohm
CANBus input: 65128 - 1638 - 0x21
Connection cable order separately

VDO SingleViu Coolant Temperature Gauge 120°C

Temperature Gauge

VDO SingleViu Coolant Temperature Gauge 120°C

Black - Hole: 52 mm - 2 1/16"
Operating voltage: 8-32 Volt DC
Range: +40°C to +120°C - ISO 1380
Analogue signal: 287.4 - 22.7 Ohm
CANBus input: 65262 - 110 - 0x18
Connection cable order separately

VDO SingleViu Hydraulic Temperature Gauge 120°C

Temperature Gauges

VDO SingleViu Hydraulic Temperature Gauge 120°C

Black - Hole: 52 mm - 2 1/16"
Operating voltage: 8-32 Volt DC
Range: +40°C to +120°C - ISO 1414
Analogue signal: 287.4 - 22.7 Ohm
CANBus input: 65128 - 1638 - 0x21
Connection cable order separately

VDO SingleViu Hydraulic Temperature Gauge 250°F

Temperature Gauges

VDO SingleViu Hydraulic Temperature 250°F

Black - Hole: 52 mm - 2 1/16"
Operating voltage: 8-32 Volt DC
Range: 0°F to +250°F - ISO 1414
Analogue signal: 287.4 - 22.7 Ohm
CANBus input: 65128 - 1638 - 0x21
Connection cable order separately

VDO SingleViu Coolant Temperature Gauge 120°C

Temperature Gauges

VDO SingleViu Coolant Temperature Gauge 120°C

Black - Hole: 52 mm - 2 1/16"
Operating voltage: 8-32 Volt DC
Range: +40°C to +120°C - ISO 1380
Analogue signal: 287.4 - 22.7 Ohm
CANBus input: 65262 - 110 - 0x18
Connection cable order separately

VDO SingleViu Hydraulic Temperature Gauge 120°C

Temperature Gauges

VDO SingleViu 1414 Hydraulic Temperature Gauge 120°C

Black - Hole: 52 mm - 2 1/16"
Operating voltage: 8-32 Volt DC
Range: +40°C to +120°C - ISO 1414
Analogue signal: 287.4 - 22.7 Ohm
CANBus input: 65128 - 1638 - 0x21
Connection cable order separately

VDO SingleViu Hydraulic Temperature Gauge 250°F

Temperature Gauges

VDO SingleViu Hydraulic Temperature 250°F

Black - Hole: 52 mm - 2 1/16"
Operating voltage: 8-32 Volt DC
Range: 0°F to +250°F - ISO 1414
Analogue signal: 287.4 - 22.7 Ohm
CANBus input: 65128 - 1638 - 0x21
Connection cable order separately